Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale

Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale

Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale
Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale_top
Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale__after
Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale__below
Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale__front
Clamp-On Current lowest Probe DC-100KHZ Auto‑zeroing Probe Tester High Accuracy for BNC 1MΩ <100pF new arrival Tester outlet sale__left

Description

Feature:
1. Clamp‑on current probe, the range supports 100mV/A and 10mV/A, with small error.
2. No need to disconnect the circuit, bid farewell to tedious circuit frequency measurement, and make the measurement easier.
3. The current clamp can be used with any test instrument with BNC interface and impedance of 1MΩ and <100pF.
4. Easy to install and use, stable performance, high measurement accuracy, it is a practical electrical equipment.
5. This current clamp has an auto‑zeroing position so that it can be used in different environments.


Specification:

Item Type: Clip-On Current Probe
Material: ABS
Length: Approx. 230mm / 9.1in
Range 100mV/A 10mV/A Current Range 50mA-10A peak 10A-100A Peak Percent Error of Output Signal 3%±5mV 500m-10A Peak Value: 4%±500uV
10-100A Peak Value: 15% Maximum At 100A Frequency Range (-3dB) DC-100KHZ Phase DC-65HZ: <1.5° DC-65HZ: <1° Load Impedance ≥1MΩ and ≤100PF Insertion Impedance 0.01Ω Noise 6mV 600uV Conversion Rate 0.3V/uS 20mV/US Rise/Fall Time 3uS <4uS Measurement Condition 23℃±5℃, 20-75%RH, sinusoidal frequency 48-65HZ, external magnetic field <40A/m, no current-carrying wire nearby, center test sample, load impedance 1M Power Supply 1X6F22 9V alkaline dry battery (not included) Low Battery Indicator When >6.5V, the LED is green Overload Indication The red LED indicates that the measurement current is too large and the range needs to be changed Maximum Insertion in Jaw Diameter 11.8mm / 0.5in Output 2m coaxial cable, terminal with insulated BNC socket Operating Temperature 0-50℃ Storage Humidity  -3-80℃ Operating Relative H






















Features & details

Features

  • Clamp‑on current probe, the range supports 100mV/A and 10mV/A, with small error.
  • No need to disconnect the circuit, bid farewell to tedious circuit frequency measurement, and make the measurement easier.
  • The current clamp can be used with any test instrument with BNC interface and impedance of 1MΩ and <100pF.
  • Easy to install and use, stable performance, high measurement accuracy, it is a practical electrical equipment.
  • This current clamp has an auto‑zeroing position so that it can be used in different environments.

Product information